Power Over Ethernet
LAN Switch
This 60 Watts, high power Single port industrial POE Injector is equipped with our high efficiency ColdDesign technology to provide 60 watts power to your security equipment by a 4-pin selectable dip switch. The ColdDesign technology will not only power up your PD device, also reduce the excessive heat problem to a minimum. It accepts the input voltage from 44VDC to 56VDC to meet IEEE802.3af/at required voltage. This built-in 4 pin dip switches are able to select POE for Mode B or Mode A, to select standard IEEE802.3at 30Watts or high power 36Watts, and to select 2 pair or 4 pair for 30/36Watts or 60/72Watts power output. It is being rigorously tested for your Security, Transportation and Telco application.
Specification | |
---|---|
IEEE Standard | IEEE 802.3 10Base-T Ethernet IEEE 802.3u 100Base-TX Fast Ethernet IEEE 802.3ab 1000Base-T Gigabit Ethernet IEEE802.3af for POE IEEE802.3at for POE+ |
Network Connector : | 1xRJ-45 10/100/1000BaseT(X) Data 1xRJ-45 10/100/1000BaseT(X) PSE with POE Output power |
Network Cable | UTP/STP above Cat.5e Cable EIA/TIA-568 10-ohm (100m) |
Protocol | CSMA/CD |
LED | PW1(power 1) Green: ON- power good, OFF- power failed PW2(power 2) Green: ON- power good, OFF- power failed Mode A : ON - End Span PD detected Mode B: ON - Mid Span PD detected 4 Pair: ON - 60W PSE in active mode. OFF - 30W PSE in active mode. |
POE Pin Assignment | Default: Mode A (End Span) V+, V+, V-, V- for pin 1, 2, 3, 6 DIP switch setting can be changed to Mode B, V+, V+, V-, V- for pin 4, 5, 7, 8 |
DIP Switch | To select 2 pair (30/36Watts) or 4 pair (60/72Watts) To select Mode A, or Mode B To select standard IEEE802.3at 30watts or high power POE 36Watts |
Reserve polarity protection | Present |
Overload current protection | Present |
Power Supply | 2 Redundant power source 44V-56V VDC Power Input, |
Power Consumption | 1 W@48 VDC Without POE |
POE power | Maximum POE power 72watts at 56VDC input |
Removable Terminal Block | Provide 4 pin terminal block Wire range: 0.34mm^2 to 2.5mm^2 Solid wire (AWG):12-24/14-22 Stranded wire(AWG): 12-24/14-22 Torque:5lb-In/0.5Nm/0.56Nm Wire Strip length: 7-8mm |
Operating Temperature | -40℃~75℃ fully tested. |
Operating Humidity | 5% to 95% (Non-condensing) |
Storage Temperature | -40℃~85℃ |
MTBF (mean time between | 5,510,304 hrs ( MIL-HDBK-217F) at 25℃ |
Housing | Rugged Metal ,IP30 Protection |
Case Dimension (W X D X H) | 103.5mmx32mmx81.5mm (LxWxD) |
Installation mounting | DIN Rail mounting and Wall Mounting | Certifications: |
EN55022/24 | ITE equipment |
EN50155 | Railways Applications Electronic Equipment used on Rolling Stock |
EN55011 | Industrial, Scientific and Medical (ISM) equipment |
EN50121-3-2 | Railway Applications - Electromagnetic Compatibility - Part 3-2 Rolling Stock - Apparatus |
EN50121-4(pending) | Railway Applications – Electromagnetic Compatibility – Part4 Emissions and Immunity of the Signaling and Telecommunications Apparatus |
Safety | IEC EN60950-1 |
EMC/EMS | CE, FCC, VCCI |
EMI | FCC Part 15 Subpart B Class A, CE EN 55022 Class A |
EN 50155 / EN 60068-2-6 | Vibration |
EN 50155 / EN 60068-2-27 | Shock |
EN 50155 / EN 60068-2-32 | Free Fall |